Overview
Most older attics are under-insulated. This calculator shows how many extra inches of insulation reach your target R-value and the volume to order.
Enter the R-value you are aiming for, what is already there and the insulation type you plan to add.
Worked examples
| Inputs | Result |
|---|---|
| UnitsImperial (ft, miles, gallons)Target R-value49Existing R-value11Insulation typeBlown cellulose (R-3.5/in)Attic floor area (ft² or m²)1,000 | Add 10.9 in of insulation (27.6 cm)Volume: 904.76 ft³ (25.62 m³)Adds R-38 for a total of R-49 |
Show 2 more examples
| UnitsImperial (ft, miles, gallons)Target R-value38Existing R-value0Insulation typeBlown fiberglass (R-2.5/in)Attic floor area (ft² or m²)1,200 | Add 15.2 in of insulation (38.6 cm)Volume: 1,520 ft³ (43.04 m³)Adds R-38 for a total of R-38 |
| UnitsImperial (ft, miles, gallons)Target R-value60Existing R-value19Insulation typeFiberglass batts (R-3.1/in)Attic floor area (ft² or m²)800 | Add 13.2 in of insulation (33.6 cm)Volume: 881.72 ft³ (24.97 m³)Adds R-41 for a total of R-60 |
Attic Insulation by target r-value
With the calculator's starting values, the result is Add 10.9 in of insulation. The table shows how it changes with the target r-value.
| Target R-value | Attic Insulation |
|---|---|
| 30 | Add 5.4 in of insulation |
| 40 | Add 8.3 in of insulation |
| 49starting value | Add 10.9 in of insulation |
| 50 | Add 11.1 in of insulation |
| 60 | Add 14 in of insulation |
| 70 | Add 16.9 in of insulation |
Other inputs: Units: Imperial (ft, miles, gallons) · Existing R-value: 11 · Attic floor area: 1,000 ft². Change them in the calculator above for your own numbers.
How it works
Insulation R-values add up. The extra R needed is the target minus the existing R-value; dividing by the R-value per inch of the chosen material gives the depth to add, and depth × area gives the volume.
The formula
| R per inch | Blown fiberglass ≈ 2.5, cellulose ≈ 3.5, fiberglass batts ≈ 3.1, mineral wool ≈ 3.3 |
Practical tips
- Seal air leaks around lights, pipes and the attic hatch before adding insulation.
- Keep insulation clear of eave vents with baffles so the roof can breathe.
- Blown insulation settles; manufacturers quote a settled depth on the bag chart.
Frequently asked questions
What R-value should my attic have?
The US Department of Energy recommends R-30 to R-60 depending on climate zone; R-49 is typical for cold climates.
How deep is R-38?
About 15 in of blown fiberglass or 11 in of cellulose.