Overview

Tankless water heaters are sized by flow and temperature rise, rather than tank capacity. This calculates the output you need.

Add up the flow of the fixtures you run at once: a shower is about 2 gal/min, and a kitchen faucet about 1.5. Your incoming water temperature depends on your climate.

Worked examples

InputsResult
UnitsImperial (ft, miles, gallons)Peak hot water flow (gal/min or L/min)5Incoming water temperature (°F or °C)50Desired hot water temperature (°F or °C)120Required output: 175,000 BTU/hourElectric equivalent: 51.3 kWTemperature rise: 70 °F
Show 2 more examples
UnitsImperial (ft, miles, gallons)Peak hot water flow (gal/min or L/min)3Incoming water temperature (°F or °C)60Desired hot water temperature (°F or °C)120Required output: 90,000 BTU/hourElectric equivalent: 26.4 kWTemperature rise: 60 °F
UnitsImperial (ft, miles, gallons)Peak hot water flow (gal/min or L/min)7Incoming water temperature (°F or °C)40Desired hot water temperature (°F or °C)120Required output: 280,000 BTU/hourElectric equivalent: 82.1 kWTemperature rise: 80 °F

Required output by peak hot water flow

With the calculator's starting values, the required output is 175,000 BTU/hour. The table shows how it changes with the peak hot water flow.

Peak hot water flow (gal/min)Required output (BTU/hour)
3105,000 BTU/hour
4140,000 BTU/hour
5starting value175,000 BTU/hour
6210,000 BTU/hour
7245,000 BTU/hour

Other inputs: Units: Imperial (ft, miles, gallons) · Incoming water temperature: 50 °F · Desired hot water temperature: 120 °F. Change them in the calculator above for your own numbers.

How it works

Heating one gallon by 1 °F takes about 8.33 BTU, or about 500 BTU per hour at a flow of 1 gal/min. Multiply by flow and rise to get output. This is heat delivered to the water, so check a model’s rated flow at your temperature rise rather than its input rating. Gas lines and electric services may need upgrades, which a licensed installer can confirm.

The formula

BTU/hour = 500 × gal/min × temperature rise
riseHot water temperature − incoming temperature
kWBTU/hour ÷ 3,412

Practical tips

  • 5 gal/min with a 70 °F rise needs 175,000 BTU/hour, or about 51.3 kW.
  • Use your coldest incoming water temperature, since winter is the hardest test.
  • Low-flow fixtures can cut your required size considerably.

Frequently asked questions

Why does climate matter?

Colder incoming water needs a bigger rise, which lowers the flow a given heater can supply.

Can electric tankless serve a whole house?

Sometimes, but high outputs may need a large electrical service. Gas units are often used for high flows.