Overview
RAID combines disks for speed, redundancy or both. Each level trades raw capacity for protection in a different way.
Choose the level, the number of disks and the disk size.
Worked examples
| Inputs | Result |
|---|---|
| RAID levelRAID 5 (single parity)Number of disks4Disk size (TB)8 | Usable capacity: 24 TB of 32 TB rawEfficiency: 75%Fault tolerance: 1 diskRAID is not a backup: keep separate copies of important data. |
Show 2 more examples
| RAID levelRAID 6 (double parity)Number of disks6Disk size (TB)12 | Usable capacity: 48 TB of 72 TB rawEfficiency: 66.7%Fault tolerance: 2 disksRAID is not a backup: keep separate copies of important data. |
| RAID levelRAID 10 (striped mirrors)Number of disks8Disk size (TB)4 | Usable capacity: 16 TB of 32 TB rawEfficiency: 50%Fault tolerance: 1 disk per mirrored pairRAID is not a backup: keep separate copies of important data. |
Usable capacity by disk size
With the calculator's starting values, the usable capacity is 24 TB of 32 TB raw. The table shows how it changes with the disk size.
| Disk size (TB) | Usable capacity (TB) |
|---|---|
| 4 | 12 TB of 16 TB raw |
| 5 | 15 TB of 20 TB raw |
| 6 | 18 TB of 24 TB raw |
| 7 | 21 TB of 28 TB raw |
| 8starting value | 24 TB of 32 TB raw |
| 9 | 27 TB of 36 TB raw |
| 10 | 30 TB of 40 TB raw |
| 11 | 33 TB of 44 TB raw |
| 12 | 36 TB of 48 TB raw |
Other inputs: RAID level: RAID 5 (single parity) · Number of disks: 4. Change them in the calculator above for your own numbers.
How it works
RAID 0 uses all disks with no protection; RAID 1 mirrors; RAID 5 gives up one disk to parity; RAID 6 gives up two; RAID 10 mirrors pairs and stripes them, using half the raw space.
The formula
| n | Number of identical disks |
Practical tips
- Four 8 TB disks in RAID 5 give 24 TB usable and survive one failure.
- Rebuilding large RAID 5 arrays takes a long time, so RAID 6 is often preferred above about 8 TB per disk.
- RAID is about uptime; you still need backups.
Frequently asked questions
Which RAID is fastest?
RAID 0, but one disk failure loses everything.
Can I mix disk sizes?
Most arrays then treat all disks as the size of the smallest.