Overview

Flow rate depends on a pipe’s cross-section and how fast the fluid moves. It is a basic check when sizing pipes and pumps.

Choose what to solve for and enter the inside diameter.

Worked examples

InputsResult
Solve forFlow rate from velocityInside diameter (mm)50Velocity (m/s) or flow (L/min)2Flow rate: 235.6 L/min (3.927 L/s)62.24 US gal/min
Show 2 more examples
Solve forFlow rate from velocityInside diameter (mm)25Velocity (m/s) or flow (L/min)1.5Flow rate: 44.18 L/min (0.7363 L/s)11.67 US gal/min
Solve forVelocity from flow rateInside diameter (mm)100Velocity (m/s) or flow (L/min)500Velocity: 1.061 m/sPipe area: 7,854 mm²

Flow rate by inside diameter

With the calculator's starting values, the flow rate is 235.6 L/min. The table shows how it changes with the inside diameter.

Inside diameter (mm)Flow rate (L/min)
3084.82 L/min
40150.8 L/min
50starting value235.6 L/min
60339.3 L/min
70461.8 L/min

Other inputs: Solve for: Flow rate from velocity · Velocity (m/s) or flow: 2 L/min. Change them in the calculator above for your own numbers.

How it works

Flow = area × velocity, where area = π ÷ 4 × d².

The formula

Q = (π ÷ 4) × d² × v
dInside diameter
vAverage velocity

Practical tips

  • A 50 mm pipe at 2 m/s carries about 236 L/min.
  • Doubling the diameter gives four times the flow at the same speed.
  • Water systems usually stay around 1–3 m/s to limit noise and wear.

Frequently asked questions

Inside or outside diameter?

Inside, which depends on the pipe schedule.

Does this include pressure loss?

No; it relates only flow, area and velocity.