Overview

Heat flows from warm to cold through walls and windows. U-values show how quickly.

Enter the area, U-value and the indoor and outdoor temperatures.

Worked examples

InputsResult
Area (m²)20U-value (W/m²·K)0.5Indoor temperature (°C)20Outdoor temperature (°C)0Heat flow: 200 WEnergy per day: 4.8 kWhR-value: 2 m²·K/W (US R-11.36)
Show 2 more examples
Area (m²)2U-value (W/m²·K)5Indoor temperature (°C)21Outdoor temperature (°C)-5Heat flow: 260 WEnergy per day: 6.24 kWhR-value: 0.2 m²·K/W (US R-1.136)
Area (m²)100U-value (W/m²·K)0.25Indoor temperature (°C)20Outdoor temperature (°C)5Heat flow: 375 WEnergy per day: 9 kWhR-value: 4 m²·K/W (US R-22.71)

Heat flow by area

With the calculator's starting values, the heat flow is 200 W. The table shows how it changes with the area.

Area (m²)Heat flow
10100 W
12.5125 W
15150 W
17.5175 W
20starting value200 W
22.5225 W
25250 W
27.5275 W
30300 W

Other inputs: U-value: 0.5 W/m²·K · Indoor temperature: 20 °C · Outdoor temperature: 0 °C. Change them in the calculator above for your own numbers.

How it works

Heat flow = U × area × temperature difference. R-value is the inverse of U.

The formula

Q = U × A × ΔT · R = 1 ÷ U
UHeat transfer coefficient (W/m²·K)

Practical tips

  • 20 m² at U = 0.5 with a 20 °C difference loses 200 W, or 4.8 kWh a day.
  • A single-glazed window loses about ten times more than an insulated wall per square meter.
  • Air leaks add to this, sometimes substantially.

Frequently asked questions

How do I convert R-values?

Multiply metric R by 5.678 to get US R-value.

What is a good U-value?

New walls are often 0.2–0.3 and good windows about 1.